ACMAS Technologies Pvt. Ltd.
Vibration and Temperature & Humidity & Vibration Combined Test Chamber offer combined temperature, humidity, and/or vibration environments. Weiber models are designed for compatibility with user’s choice of electrodynamic or mechanical vibration systems. While each model is manufactured to standard designs, they may also be custom engineered to meet a wide range of stringent test requirements. The Test Chamber comes with optional capability to interface with vibration systems in both the horizontal and vertical modes of operation with rear or vertical sliding doors. The Weiber Series temperature/humidity and vibration chambers are designed to integrate with vibration systems in only the vertical mode of operation.
-
E9304A -
Keysight Technologies
Refer to the E9301A for standard power sensor features Low frequency coverage (9 kHz to 6 GHz) for EMC/EMI test applications such as the radiated immunity test (IEC61000-4-3)High sensitivity (-60 to +20 dBm) and fast measurement speed to reduce the time taken to calibrate radiated field uniformity and EMC/EMI test receivers Measure transmitter power and receiver sensitivity at Very Low Frequency (VLF) to microwave frequencies Special option available to 18 GHz Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
M9121A -
Keysight Technologies
The M9121A is a 4x64 full crosspoint switch matrix offering high-density, high-speed signal switching in a single PXI module. The 2-wire matrix allows multiple channels to be connected in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the high-speed, long-life reed relays to support signal switching up 100Vrms with 10W maximum power. The 4-wide bus is ideal to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
2732 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on "low ohms" : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Designed for meet international standards.● Supplied with high quality test leads.● BS 16 edition.
-
4132 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on "low ohms" : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Designed for meet international standards.● Supplied with high quality test leads.● BS 16 edition.
-
ACMAS Technologies Pvt. Ltd.
Weiber walk in humidity test chambers are conceptualized and designed to create test chambers to study and contemplate the effects of different environmental parameters such as humidity, temperature applications tests involving micro-organisms, plants, tissues, electronic components etc. apart from various customized industrial and research applications. Our humidity test chambers have a variety of usage in R and D laboratories, research studies and product testing facilities across the globe. Apart from that, these chambers have a variety of usages in tissue culture applications, enzyme reaction studies, growth observation studies, fermentation analysis and various other general and specialized applications in various laboratories. We specialize in both standard and customized humidity test cabinets, specifically designed to meet the challenging demands of various scientists for individual and specialized research applications.
-
KHZ43201 -
Beijing KeHuan Century EMC Technology Co,.LTD
The KHZ43201 voltage probe is a standard low resistance test probe, which meets the technical requirements for this product in the CISPR16-1 and CISPR14-1 test equipment. When measuring the interference voltage of the power grid, the artificial power supply network cannot be used at the load port, and sometimes it is necessary to use a voltage probe to measure the interference of the signal port, the load port, and the antenna port. The input impedance of the voltage probe to the ground wire is greater than 1.5KΩ, which can protect the input terminal of the receiver.
-
PFM61000-8A -
Lisun Electronics Inc.
PFM61000-8A Magnetic Field Generator is high reliability test equipment with stable performance, specially designed for electrical and electronic products for measuring immunity characteristics and requirements of normal frequency magnetic fields. It provides an accurate basis for the tested equipment in the immunity test of normal frequency magnetic field. The generator can imitate the magnetic field environments such as residential, commercial, industrial and mining enterprises, power plants, as well as middle and high substation. It fully meets IEC61000-4-8 and GB / T17626.8 standards.
-
Neutronics Manufacturing Co.
NMC''s Transformer BDV Oil Test Set is a portable unit as per relevant Indian Standard Specification IS :6792 :1992, suitable for operation on 230 / 240 Volts, A.C. 50 Hz. A three core flexible cable is connected to the unit with three pin socket to connect the mains. The H.V. Transformer is a completely dry, resin encapsulated with two H.V. terminals with mounting saddles. The center point of the transformer is earthed, so that the voltage of each terminal to earth is only half the test voltage.
-
PCI EmbeddedComputer Systems
Measurement and testing of CompactPCI® assemblies in the 3U Euro-board form factor is greatly facilitated by the use of this test adapter. Easy access to the DUT is guaranteed because the adapter has plug-in connections on 3 sides. The Modern BRIDGE design permits up to 3 CompactPCI® cards and one standard PCI® card to be inserted in one CompactPCI® slot. This allows system developers to implement a large number of tests with little effort and enables you to achieve vital time to market.
-
PCI EmbeddedComputer Systems
Measurement and testing of CompactPCI® assemblies in the 6U Euro-board form factor is greatly facilitated by the use of this test adapter. Easy access to the DUT is guaranteed because the adapter has plug-in connections on 3 sides. The Modern BRIDGE design permits up to 3 CompactPCI® cards and one standard PCI® card to be inserted in one CompactPCI® slot. This allows system developers to implement a large number of tests with little effort and enables you to achieve vital time to market.
-
Insight -
HORIBA, Ltd.
Today’s environment confronts lab managers in new, challenging ways. The current regulations demand increasingly complex test procedures that require more time and resources to execute, which counteracts the goals to improve productivity and reduce costs. Therefore, lab managers need to maximize the test cell availability by continual awareness of the current situation in their facility. They must ensure the equipment is fully functional, meets all mandatory quality standards and regulations, and is up to date with all service and maintenance requirements.
-
TWA Standard Series -
Amperis sl
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
MSP Corporation
All filter test equipment from TSI, used for testing efficiencies of filter media and a variety of air filters, including high and very high-efficiency filters, respiratory filters, cartridges, and protective garments, is known for its simple and reliable operation. All of our filter testers can determine the efficiency of filters using submicron poly- and monodisperse oil and/or sodium chloride aerosol. Additionally, TSI's filter test solutions are used to comply with various testing standards and regulations around the globe.
-
TAND220A -
Amperis sl
The measuring instrument type TAND220A complies with the international standard IEC 61620. The instrument is based on the so-called "low-amplitude, low-frequency alternating current square wave method" and allows accurate measurements of conductivity and relative permittivity. Conductivity measurement in the range of 0.01 pS/m to 20,000 pS/m allows the use of this instrument for quality control of high resistivity liquids even at room temperature. The TAND220A works with a low test voltage and also with a low test current so that it does not represent a danger for the operators.